Add to Cart
FTTH Nap Outdoor 16Cores Fiber Optic Splitter Splice Closure Junction Box KCO-GJS22 PC+ABS
KCO-1608D Fiber optic splitter closure box is new design to sastify new FTTH demand. It can install 1 pc of 1*8 PLC splitter. Make by high quality PC material, life time is longer.
Features
- Can accommodate two 1x8 PLC splitter LGX module or steel tube type;
- Anti-ultraviolet,anti- impact and waterproof function;
- Unique flip board, flip angle ≥ 180 °, fusion area and distribution area is more obvious, reducing the cable crossing;
- Fiber optic cable can go in and out of the box without cut the cable.
Specification:
Model | KCO-GJS22 |
Dimension | 290*190*110mm |
Cable diameter | Φ7-φ18mm |
Cable port | 4pcs round ports 16pcs 2*3mm drop cable ports |
Max. Split ratio | 2pcs 1x8 mini splitter |
Max. Splice tray | 1pc |
Max. Fusion splice | 24 cores |
Technical parameters:
- Optical fiber radius of curvature: ≥40mm
- Splice tray additional loss: ≤0.1dB
- Temperature range: -40°C ~ +60°C
- Anti side pressure: ≥2000N/10cm
- Impact resistance: ≥20N.m
- Waterproof level: IP65
Packing list:
Main body | 1 set |
L=400mm bare fiber buffer tube | 2 pcs |
Hoop / clamp | 2 pcs |
3x100 nylon tie | 26 pcs |
Heat shrinkable tube L=60mm | 2-72 pcs (configuration on demand) |
User manual | 1pc |
Product pictures:
Installation way:
Characterictics:
Characteristics | Value/Performance | Methods and Conditions |
Mechanical | ||
Air Tightness | No air bubble seen | Put closure under water for 15min with closure's internal air pressure set at 100kPa±5kPa. |
Remains100kPa±5kPa | Measure the internal pressure 24 hours later | |
Air Tightness after re-installation | No air bubble seen and pressure remains unchanged | Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. |
Axial Pulling | Pressure remains unchanged | Pulling force: 1000N Time: 1min Internal air pressure: 60kPa±5kPa |
Compression | Pressure remains unchanged | Applied pressure: 2000N/100mm Time: 1min Internal air pressure: 60kPa±5kPa |
Impact | Pressure remains unchanged | Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60±5kPa |
Bending | Pressure remains unchanged | Bending angle±45°(in two opposite directions) Tension: 150N No. of bending: 10 Internal air pressure: 60kPa±5kPa |
Twisting | Pressure remains unchanged | Twisting angle: ±90° Torque: 50N No. of twisting: 10 Internal air pressure: 60kPa±5kPa |
Thermal | ||
Temperature Cycling | Pressure drop ≤5kPa | Cycling range: -40 ~ +60°C Cycling time: 2hrs at -40°C, then 2hrs at +60°C No. of cycling: 3 Internal air pressure: 60kPa±5kPa |
Electrical | ||
Insulation | Resistance between metal parts:2.0x105MΩ | Soak closure into water in 1.5m-depth for 24hrs, and measure the insulation resistance after taking it out of water. |
Resistance between each metal part and ground:2.0x105MΩ | ||
High Voltage | No voltage break-downs and sparks | Soak closure into water in 1.5m-depth for 24hrs, then apply 15kV DC to the metal parts inside |